Customization: | Available |
---|---|
Media: | Gas, Oil, Water, Chemical |
Temperature: | Low Temperature |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electric actuator gate valves are crucial components in various industries, offering reliable and efficient control of fluid flow. These valves play a vital role in regulating the movement of liquids or gases through pipelines, allowing for isolation or diversion of flow as needed. In this comprehensive guide, we will delve into the world of electric actuator gate valves, providing insights into their definitions, types, working principles, and key features to help you understand these products better.
Simple structure, easy to manufacture and maintain
Small working stroke and short opening and closing time
Good sealing performance, small friction between sealing surfaces and long life
In the process of opening and closing, the friction of the sealing surface is smaller than that of the gate valve, which is wear-resistant
usually only one sealing surface, good manufacturing process, easy to maintain
Electric actuator is easy to operateDesign & Manufacture: KS B2361Construction Length: KS B2361
Flange Dimension: KS B2361
Pressure Test: KS B2361
After the test, remove stagnant water, suburban viscera, anti-rust treatment
Electric gate valve: An electric gate valve uses an electric motor instead of a handwheel. By utilizing electrical power, the actuator spins the stem to raise or lower the gate. This allows it to be operated remotely with no user on-site but requires electrical power on-site. These are also referred to as motorized gate valves.
A gate valve operates similar to other valves. To open the valve, turn the handwheel (A), which moves the gate (G) up or down on the stem (B) via the threads. A gate valve requires more than one 360° turn to open or close the valve fully. When the gate is lifted up, it opens the inlet to the outlet allowing an unobstructed passageway for the media to flow. When the gate is lowered, it closes and blocks the media flow.
The relationship between the gate's vertical travel and the flow rate is nonlinear for a gate valve, with the greatest changes occurring near-complete closure. When used to regulate flow, the relatively high velocity of the flow at partial opening results in gate and seat wear, which along with possible vibrations of the gate, shortens the valve's service life. Therefore, a gate valve should only be used for on/off control.
Technical Parameters of Valve Actuator
Power supply | conventional: single phase 220v, three phase 380v |
special: three phase 400v, 415v, 660v(50Hz, 60Hz) | |
Working environment | Ambient temperature: -20 ~ + 60 ºC (special temperature environment can be customized) |
Relative humidity: 95% (at 25 ° C) | |
Protection level | Outdoor type and explosion-proof type are IP55 (IP65, IP67, IP68 can be provided for special order) |
Working system | short time 10 minutes (15-60 minutes for special order) |
Manufacture Standard Of Gate Valve | API 600 ASME B16.34 / KS B2361 / GB/T 12234 / DIN 3352 |
Valve Connection | Flanged |
Connection Type | ANSI, JIS, DIN, GB |
Valve Material | CF8, CF8M, WCB |
Power Supply | General: 3-phase 380VAC
Special: 3-phase AC660V, AC440V, AC415V Special: 1-phase AC220V, AC110V Special: DC12V, DC24V, DC48V |
Torque Range | 50Nm to 10,000Nm |
Protection Class | IP65 |
Insulation Class | F Class |
Ambient Temperature | -4°F to 140°F |